Showing 1–16 of 20 results

Accessories for Analysing Devices AZA, AZT, AZM

Accessories for Analysing Devices AZA, AZT, AZM

Immersion assemblies
Flow assemblies
Process assemblies
Buffer solutions for pH and ORP
Calibration solutions for conductivity
temperature sensors
Wall mounting set for field housing
Pipe mounting set for field housing

Conductive Conductivity Measuring Cells, ACS-Z

Conductive Conductivity Measuring Cells, ACS-Z

COMPACT-LINE
Measuring range 1, K=0,01: 0,05 … 10 µS/cm
Measuring range 2, K=0,1: 1 … 1000 µS/cm
Measuring range 3, K=1,0: 10 µS/cm … 15 mS/cm
Connection: thread G ¾ A
Electrode Material: st. st. 1.4571 bzw. graphite
temperature range: up to 135°C (at 1 bar)
Pressure rating: up to 16 bar (at 25°C)
Temperature sensor: Pt 100 integrated

Gel-filled pH-Combined Electrode APS-X1Q

Gel-filled pH-Combined Electrode APS-X1Q

EXPERT-LINE
Measuring range: pH 0 up to 12
Connection: Pg 13,5
temperature range: -5°C up to +80°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Temperature sensor: Pt 100 possible

Gel-filled pH-Combined Electrode APS-Z

Gel-filled pH-Combined Electrode APS-Z

COMPACT-LINE
Measuring range: pH 0 up to 12
Connection: Pg 13,5
temperature range: -5°C up to +80°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Temperature sensor: Pt 100 possible

Hand-Held Conductivity Measuring Unit HND-C

Hand-Held Conductivity Measuring Unit HND-C

Measuring range:
conductivity: 0,0…200.0 mikroS up to 0,0…200.0 mS
temperature: -5,0…+100,0 °C
Accuracy:
conductivity: ± 0,5v. MV, /± 0,3 % v. FS
temperature: ± 0,2 % v. MV ± 0,3 K
Supply: 9 V battery
Hold function, min/max. -memory
Output: RS 232 or USB

Hand-Held Humidity Precision Measuring Unit HND-F

Hand-Held Humidity Precision Measuring Unit HND-F

For weight moisture or relative humidity
Measuring range: 0 -100 % rel. humidity
Accuracy: ± 0,1 / 0,2 % of rel.humidity
Supply: 9 V battery
Holding Function, min/max. -memory, alarm,
data logger, output 0-1 V, RS 232
Option: temperature-, flow measuring

Hand-Held pH, Redox, Temperature Measuring Unit HND-R

Hand-Held pH, Redox, Temperature Measuring Unit HND-R

Measuring range:
pH: 0,00 …14,00
Redox: -1999 mV…+2000 mV
Temperature: -100,0…+250,0 °C
Accuracy: ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C.
Supply: 9 V battery
hold function, min/max. -memory

Humidity Measuring Instrument with Indicator (capacitive) AFA-G

Humidity Measuring Instrument with Indicator (capacitive) AFA-G

Operating range: 0 – 100 % RH
Max. pressure: pressureless
Max. temperature: 0…60 °C
Accuracy : ± 2 % RH (5…95 % RH)
output: 4-20 mA
Plug-on display: 3,5-digit LED
Option: limit switch

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G

Operating range: temperature: -60…+200 °C
humidity: 0… 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G2

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G2

Operating range: temperature: -60…+200 °C
humidity: 0… 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA

Humidity/Temperature Transmitter AFK-E

Humidity/Temperature Transmitter AFK-E

For Industrial applications
Operating range temperature: -40…+180 °C
humidity: 0… 100 % RH
Max. pressure: 15 bar
Max. temperature: -40…60 °C (housing),
-40…+180 °C (sensor)
Accuracy of temperature: ±0, 2 °C
humidity: ± 2 % RH (0..90% RH)
Output: 0-5 V, 0-10V, 4-20 mA
Dew-point temperature, Freezing point temperature, abs. humidity, specific enthalpy,
Water-vapuor partial pressure, mixing ratio

Inductive Conductivity / Concentration and Temperature Transmitter LCI

Inductive Conductivity / Concentration and Temperature Transmitter LCI

Measuring range: 0-500 µS/cm…0-2000 mS/cm
Connection: G 1 ¼ AG – 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent®
Material: PEEK. PVDF
Max.pressure: 10 bar
Max. temperature: 120 °C (short term 140 °C)
Accuracy: 1 %

pH Electrode with Plastic Sheathing, APS-X5K

pH Electrode with Plastic Sheathing, APS-X5K

EXPERT-LINE
Measuring range: pH 0 up to 11
Connection: NPT 3/4″
Shock-proof because of plastic case
Temperature range: 0 up to 80°C
Pressure rating: up to 7 bar
Diaphragm: PTFE (teflon)
Temperature sensor: Pt 100 possible
Cable: 5 m fixed cable

Transmitter for pH-Value and ORP APM-1

Transmitter for pH-Value and ORP APM-1

COMPACT-LINE
Measuring range: pH -2 bis 16, Redox -1500..+1500 mV
Pt100/Pt1000: -50..+250°C, 0(4)-20 mA
With panel mounted housing or field mounted housing
Input: 1x pH/Redox, 2 binary inputs
1x temperature/resistance/standard signal
graphic display w. backlight max. 3 values, trend, bargraph
Output: 2 relays (SPDT) 1 supply voltage f. sensors 17 VDC
freely programmable, math and logic module
Option: plug-in boards
analogue output, power supply snesors, RS485, datalogger, Profibus, relays

Transmitter for Specific Conductivity, ACM-1

Transmitter for Specific Conductivity, ACM-1

COMPACT-LINE
measuring range: 0 up to 200 mS/cm
With panel mounted housing or field mounted housing
Input: 1x conductivity/resistance/TDS, 2 binary inputs
1x temperature/resistance/standard signal
graphic display w. backlight max. 3 values, trend, bargraph
Output: 2 relays (SPDT) 1 supply voltage f. sensors 17 VDC
freely programmable, math and logic module
Option: plug-in boards
analogue output, power supply snesors, RS485, datalogger, Profibus, relays)

Transmitter for Turbidity Meter ATT-K

Transmitter for Turbidity Meter ATT-K

COMPACT-LINE
0 up to 200 mS/cm
With panel mount housing or field mounting housing
Display of conductivity and temperature with LEDs
analogue actual-value output scaleable
2 relays for control functions (PID) programmable
2 binary inputs
1 binary output (alarm contact or temperature limit contact)