Showing 17–32 of 73 results

ET-7000 Series Taper Gage

ET-7000 Series Taper Gage

External Taper Gage

The ET-7000 Series of gages inspect variations in connection taper of external threads ranging from 0”-24” for API threads. Each model covers a specific range of connection sizes..
Each gage is shipped with .072” diameter contact points, however; each set of contact points is interchangeable to allow measuring different thread forms. Contact point diameters are manufactured to tolerances of +.0002”.
The ET-7000 gage requires no setting master to inspect parts.

Gel-filled pH-Combined Electrode APS-X1Q

Gel-filled pH-Combined Electrode APS-X1Q

EXPERT-LINE
Measuring range: pH 0 up to 12
Connection: Pg 13,5
temperature range: -5°C up to +80°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Temperature sensor: Pt 100 possible

Gel-filled pH-Combined Electrode APS-Z

Gel-filled pH-Combined Electrode APS-Z

COMPACT-LINE
Measuring range: pH 0 up to 12
Connection: Pg 13,5
temperature range: -5°C up to +80°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Temperature sensor: Pt 100 possible

Hand-Held Conductivity Measuring Unit HND-C

Hand-Held Conductivity Measuring Unit HND-C

Measuring range:
conductivity: 0,0…200.0 mikroS up to 0,0…200.0 mS
temperature: -5,0…+100,0 °C
Accuracy:
conductivity: ± 0,5v. MV, /± 0,3 % v. FS
temperature: ± 0,2 % v. MV ± 0,3 K
Supply: 9 V battery
Hold function, min/max. -memory
Output: RS 232 or USB

Hand-Held Humidity Precision Measuring Unit HND-F

Hand-Held Humidity Precision Measuring Unit HND-F

For weight moisture or relative humidity
Measuring range: 0 -100 % rel. humidity
Accuracy: ± 0,1 / 0,2 % of rel.humidity
Supply: 9 V battery
Holding Function, min/max. -memory, alarm,
data logger, output 0-1 V, RS 232
Option: temperature-, flow measuring

Hand-Held pH, Redox, Temperature Measuring Unit HND-R

Hand-Held pH, Redox, Temperature Measuring Unit HND-R

Measuring range:
pH: 0,00 …14,00
Redox: -1999 mV…+2000 mV
Temperature: -100,0…+250,0 °C
Accuracy: ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C.
Supply: 9 V battery
hold function, min/max. -memory

Humidity Measuring Instrument with Indicator (capacitive) AFA-G

Humidity Measuring Instrument with Indicator (capacitive) AFA-G

Operating range: 0 – 100 % RH
Max. pressure: pressureless
Max. temperature: 0…60 °C
Accuracy : ± 2 % RH (5…95 % RH)
output: 4-20 mA
Plug-on display: 3,5-digit LED
Option: limit switch

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G

Operating range: temperature: -60…+200 °C
humidity: 0… 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G2

Humidity/ Temperature Measuring Instrument (capacitive) AFK-G2

Operating range: temperature: -60…+200 °C
humidity: 0… 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA

Humidity/Temperature Transmitter AFK-E

Humidity/Temperature Transmitter AFK-E

For Industrial applications
Operating range temperature: -40…+180 °C
humidity: 0… 100 % RH
Max. pressure: 15 bar
Max. temperature: -40…60 °C (housing),
-40…+180 °C (sensor)
Accuracy of temperature: ±0, 2 °C
humidity: ± 2 % RH (0..90% RH)
Output: 0-5 V, 0-10V, 4-20 mA
Dew-point temperature, Freezing point temperature, abs. humidity, specific enthalpy,
Water-vapuor partial pressure, mixing ratio

Indicators Gages

Indicators Gages

Gagemaker sells replacement indicators for all Gagemaker products, as well as indicators for many special applications. These instruments conform to AGD standards, which ensures excellent performance and interchangeability.
Indicators include various resolutions and travel, depending on the application. Both inch and metric graduations are available. The smallest graduations for inch are: .0001”, .0005”, and .001”, while the smallest graduations for metric are: 0.005 mm and 0.01 mm.

Inductive Conductivity / Concentration and Temperature Transmitter LCI

Inductive Conductivity / Concentration and Temperature Transmitter LCI

Measuring range: 0-500 µS/cm…0-2000 mS/cm
Connection: G 1 ¼ AG – 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent®
Material: PEEK. PVDF
Max.pressure: 10 bar
Max. temperature: 120 °C (short term 140 °C)
Accuracy: 1 %

Internal Taper Gage

Internal Taper Gage

The IT-6000 Series of gages inspect variations in connection taper of internal threads ranging from 1 1/2” – 24” for API threads. Each model covers a specific range of connection sizes.
Each gage is shipped with .072” diameter contact points, however; each set of contact points is interchangeable to allow measuring different thread forms. Contact point diameters are manufactured to tolerances of +.0002”.
The IT-6000 gage requires no setting master to inspect parts.

Internal Thread Height Gages

Thread Height Gage Internal and External Thread Height

The TH-3000 series of gages inspect variations in thread height for a variety of thread forms. All gage models use a precision contact point that seats in the thread of the part during inspection. The gages are supplied with various base configurations to fit the particular thread form being inspected.
Some of the TH-3000 gages require zeroing on a setting standard before inspecting parts.